• Home
  • About
  • Standard Pilots
    • Standard Adsorption Pilot Plants
    • Standard Dissolved Air Flotation Pilot Plants
    • Standard Granular Media Filtration Pilot Plants
    • Standard Coagulation, Flocculation, and Sedimentation Pilot Plants
    • Standard Ozonation Pilot Plants
    • Standard Pilot Module Enclosure
  • Lease Pilots
  • Custom Pilots
    • Biological Filtration Pilot Plants
    • Custom Flocculation, Sedimentation, and Coagulation Pilot Plants
    • Granular Media Filtration Pilot Plants
    • Ozonation Pilot Plants
    • Reverse Osmosis (RO) Pilot Plants
    • Ultra Filtration Pilot Plants
    • Custom Electrolytic Cell Treatment Pilot Plants
  • Careers
  • Resources
  • Contact

801-487-9255 techsupport@intuitech.com

sales@intuitech.com
Intuitech
  • Home
  • About
  • Standard Pilots
    • Standard Adsorption Pilot Plants
    • Standard Dissolved Air Flotation Pilot Plants
    • Standard Granular Media Filtration Pilot Plants
    • Standard Coagulation, Flocculation, and Sedimentation Pilot Plants
    • Standard Ozonation Pilot Plants
    • Standard Pilot Module Enclosure
  • Lease Pilots
  • Custom Pilots
    • Biological Filtration Pilot Plants
    • Custom Flocculation, Sedimentation, and Coagulation Pilot Plants
    • Granular Media Filtration Pilot Plants
    • Ozonation Pilot Plants
    • Reverse Osmosis (RO) Pilot Plants
    • Ultra Filtration Pilot Plants
    • Custom Electrolytic Cell Treatment Pilot Plants
  • Careers
  • Resources
  • Contact

Back to Lease Equipment

Pilot Module Enclosure B500

Enclosure consists of a galvanized tube frame with insulated panel walls. Enclosure includes a waterproof ¼ inch thick spray-on polyester floor coating and a 10’ working height inside the building, as well as an insulated floor, ceiling, and walls. Unit includes an entry/egress door, ventilation fan, wet location lighting, a power distribution panel, emergency lighting, a piping corridor recessed in the floor, remote access module mast, and combination heating/AC (2.5 tons of cooling/ 5KW heater) through a centralized HVAC system. The enclosure has space for up to 3 Intuitech pilot modules.

Specifications

Module B500
Configuration E401412-2ED-0SD-1PS-HVAC-SVN
Exterior Dimensions 42.9′ (13,062 mm) L x 11′ (3,353 mm) W x 11.5′ (3,508 mm) H
Internal Dimensions 39′ (11,887 mm) L x 10′ (3,048 mm) W x 10′ (3,048 mm) H
End Door Clearance 70.5″ (1,791 mm) W x 95.2″ (2,418 mm) H
Snow Load Design 75 lbs/ft2 (ground), 55 lbs/ft2 (flat roof)
Wind Load Design 35 mph (3 sec gust, ultimate basis), Exposure Category C
Seismic Design Ss:1.5, S1:0.6, Sds:1.2, Sd1:0.68, Class D
Power 240 V AC, 1 phase, 60 Hz, 62.5 A or
480 V AC, 1 phase, 60 Hz, 31.2 A
Empty Weight 25,500 lbs (11,567 kg)
Maximum Loaded Weight 40,000 lbs (18,144 kg)