Granular Media Filtration Pilot Module F500
Module consists of an influent reaction tank, three constant rate pressure filters, an air scour system, and a backwash system. Each filter is independent with automatic flow control and can be configured for online or standby operation. Backwashing can be initiated manually by an operator in the manual mode, or by runtime or headloss in the automatic mode. The backwash flow is also automatic with PID flow control. Only one filter may be backwashed at a time. Other features include automatic data logging of key parameters, remote monitoring and control using a standard web browser, and email alarm notification.
Specifications
Module | F500 (1215) |
Configuration | F3(30 inch)(42 inch)-PAR-(0-75 GPM)-(Hach Ultraturb)-0CF |
Filters | 3 @ 30 inch diameter (762 mm) x 62 inch height (1,575 mm) |
Maximum Media Depth | 42 inch (1,067 m) |
Flow Configurations | Parallel |
Maximum Filtration Rate | 0…75 gpm (0…294 L/min) |
Backwash Rate | 6.1…20.0 gpm/ft2 (15.0…49.0 m/h) |
Reaction Tank Volume | 90 gal (340 L) |
Air Scour Rate | 1.0…3.0 scfm/ft2 (18.3…54.9 m/h) |
Turbidimeters | Hach Ultraturb |
Power | 208 V AC, 3 phase, 60 Hz, 11.7 A or 230 V AC, 3 phase, 60 Hz, 12.9 A or 480 V AC, 3 phase, 60 Hz, 5.8 A |
Shipping Dimensions | 149″ (3.78 m) L x 53″ (1.35 m) W x 103″ (2.62 m) H |
Dry Weight | 2700 lbs (1,225 kg) |
Operating Weight | 8200 lbs (3,719 kg) |