Custom Granular Media Filtration Pilot Plants
 |
|
 |
|
Flow Rate: 1.8...7.0 gpm
Filtration Rate: 2.7...12.1 gpm
Maximum Headloss: 10.6 ft H2)
Features: 3 independent gravity fed
filter columns. Each filter is
equipped with the instrumentation to measure and
monitor the various process variables.
|
 |
|
 |
|
|
Total Flow Rate: 210 gpm
Filters:
3 @ 30"
Maximum Media Depth:
42"
Filtration Rate: 2.0...14.3 gpm/sf
Backwash Rate: 6.1...20.0 gpm/sf
Air Scour Rate: 1.0...3.0 scfm/sf
Reaction Tank Volume: 90 gal
Features: Automatic operation, sample ports,
headloss instruments, data acquisition, web enabled,
email alarm notification.
|
 |
|
 |
|
|
Maximum Total Flow Rate: 8.0 gpm
Filter Columns: 4
Filter Column Dimension:
6"
Column Height: 118"
Headloss: 0...31'
Backwash Tank
Capacity: 150 gal
Features: Automatic operation, sample ports,
turbidity and headloss instruments, data
acquisition, web enabled, email alarm notification.
|
 |
|
 |
|
Flow Rate: 8.0 gpm
Filters: 2 @ 12 in
Maximum Media Depth: 36 in
Filtration Rate: 0.51...5.10 gpm/sf
Backwash Rate: 2.5...17.8 gpm/sf
Backwash Tank Capacity: 250 gal
Features: Filters can be operated
independently, in parallel, or in a series.
|
 |
|
|
|

|
|
|
Max. Combined Flow Rate: 32 gpm (133 L/min)
Filter Columns: 2
Filter Column Dimension:
10.5 in (270 mm)
Filtration Rate: 0.43...21.5 gpm/ft2
(1.1...52.6 m/h)
Max. Media Depth: 72
in (1.83 m)
Features: Manual operation, online
instrumentation, square columns, constant head
tanks, peristaltic feed pumps
|
 |
|
 |
|
Flow Rate: 9...377.0 kL/d
Bachwash Rate: 400...1200 kL/d
Air Scour Rate:
15...50 m3/h
Chemical Feed Rate:
0.25...95 mL/m
Filtration Tank Capacity: 339 L
Features: Automatic operation, data acquisition,
Web enabled, email alarm notification, online
instrumentation, air scour
|
 |
|
|
|

|
|
Max. Combined Flow Rate: 2 gpm (7.6 L/min)
Filter Columns: 4
Filter Column Diameter:
4 in (100 mm)
Max. Media Depth: 32
in (0.8 m)
Filtration Rate: 2.3...22.9 gpm/ft2
(5.6...56.0 m/h)
Features: Manual operation, feed pump, glass
columns, polypropylene piping
|
 |
|
|
 |
|
|
Filter Columns: 7
Filter Column Dimension:
4 in (106 mm)
Filtration Rate: 3.45...8.04 gpm/ft2
(13.1...30.4 L/h)
Max. Media Depth: 72
in (1.83 m)
Features: Automatic operation, modulated valve flow
control, data acquisition,
Web enabled, email alarm notification, online
instrumentation
|
 |
|
 |
|
Filtration Rate: 1.0...8.0 gpm/ft2
Backwash Rate: 3.6...48.5 gpm/ft2
Max Pressure:
150 psi @ 73 deg F
Max Temperature: 100
deg F
Features: Automatic operation, turbidity and headloss
instrumentation
|
 |
|
|
 |
|
Max. Combined Flow Rate: 5 gpm (18.9 L/min)
Filter Columns: 3
Filter Column Diameter:
6 in (150 mm)
Max. Media Depth: 72
in (1.83 m)
Filtration Rate: 6.0...10.1 gpm/ft2
(14.7...24.7 m/h)
Backwash Tank
Capacity: 200 gal
Backwash Rate:
4.0...24.3 gpm/ft2
(9.8...59.4 m/h)
Features: Automatic operation, data acquisition,
Web enabled, email alarm notification, online
instrumentation, on-board backwash tank, air scour
|
 |
|
|
 |
|
Max. Combined Flow Rate: 13 gpm (51.1 L/min)
Filter Columns: 3
Filter Column Diameter:
6 in (150 mm)
Max. Media Depth: 90
in (2.29 m)
Filtration Rate: 1...9 gpm/ft2
(2.4...22.0 m/h)
Backwash Rate:
2.5...25.0 gpm/ft2
(6.1...61.0 m/h)
Features: Automatic operation, modulated valve
flow control, data acquisition, Web enabled, email
alarm notification, online instrumentation
|
 |
|
|
|
|
|
|
|
|